Product Description Of 500MCm XLPE Insulated Copper Power Cable
Product standard:
GB/T12706.1-2008
Application:
This product is suitable for power transmission and distribution line of rated voltage (U0/U) 0.6/1.0KV line.
Technical Parameter:
When the cable is running normally, the Maximum temperature of conductor is 90ºC; and is 250 ºC when the short circuit (Max. last 5s) happens.
The ambient temperature of installation shall not lower than 0 degrees.
Minimum bending radius is 12 D ("D" refers to cable diameter)
Single Core Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
1*1.5 | 0.7 | 1.5 | 6 | 53 | 53 | ≤12.1 | ≤12.1 | 3.5 | 26 | 26 | 33 | 32 |
1*2.5 | 0.7 | 1.5 | 6 | 68 | ≤7.41 | 3.5 | 34 | 43 | ||||
1*4 | 0.7 | 1.5 | 7 | 87 | 64 | ≤4.61 | ≤7.41 | 3.5 | 44 | 35 | 56 | 42 |
1*6 | 0.7 | 1.5 | 7 | 110 | 73 | ≤3.08 | ≤4.61 | 3.5 | 56 | 45 | 70 | 54 |
Two Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
2*2.5 | 0.7 | 1.8 | 11.8 | 151 | 118 | ≤7.41 | ≤12.1 | 3.5 | 26 | 20 | 35 | 27 |
2*4 | 0.7 | 1.8 | 12.7 | 198 | 146 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
2*6 | 0.7 | 1.8 | 13.7 | 250 | 173 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
2*10 | 0.7 | 1.8 | 16.3 | 374 | 245 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Three Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
3×1.5 | 0.7 | 1.5 | 10 | 145 | - | ≤12.1 | - | 3.5 | 20 | - | 27 | - |
3×1.6 | 0.7 | 1.5 | 11 | 185 | 140 | ≤7.41 | ≤12.1 | 3.5 | 26 | 20 | 35 | 27 |
3×4 | 0.7 | 1.5 | 12 | 250 | 175 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
3×6 | 0.7 | 1.5 | 13 | 320 | 210 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
3×10 | 0.7 | 1.5 | 15 | 450 | 260 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Four Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
4×4 | 0.7 | 1.5 | 13 | 253 | 155 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
4×6 | 0.7 | 1.5 | 14 | 337 | 184 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
4×10 | 0.7 | 1.5 | 16 | 501 | 258 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Three Cores+One Core Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
3×4+1×2.5 | 0.7 | 1.5 | 13 | 236 | 147 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
3×6+1×4 | 0.7 | 1.5 | 14 | 316 | 187 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
3×10+1×6 | 0.7 | 1.5 | 16 | 461 | 234 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Three Cores+Two Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
3×4+2×2.5 | 0.7 | 1.5 | 13.9 | 309 | 202 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
3×6+2×4 | 0.7 | 1.5 | 15.3 | 413 | 219 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
3×10+2×6 | 0.7 | 1.5 | 18.2 | 603 | 338 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Four Cores+One Core Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
4×4+1×2.5 | 0.7 | 1.5 | 14.5 | 331 | 214 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
4×6+1×4 | 0.7 | 1.5 | 15.9 | 435 | 259 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
4×10+1×6 | 0.7 | 1.5 | 18.9 | 649 | 359 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Five Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
5×4 | 0.7 | 1.5 | 14.5 | 349 | 223 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
5×6 | 0.7 | 1.5 | 15.8 | 460 | 271 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
5×10 | 0.7 | 1.5 | 19.3 | 699 | 384 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Related Product Picture
Exhibition:
Certificates
Packaging & Shipping
All cable For exporting are well packed and protected by wooden drum or Wood and Steel Drum.The packing material is depended on the weight and size of cable.The good information, manufacture information, and the client's information is firmly printed on each size of drum.
After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.
The size of the container is chosed according to weight of total loaded goods or as per the client's requirement.