• IEC Standard Low Voltage Steel Tape Armoured Cable
  • IEC Standard Low Voltage Steel Tape Armoured Cable
  • IEC Standard Low Voltage Steel Tape Armoured Cable
  • IEC Standard Low Voltage Steel Tape Armoured Cable
  • IEC Standard Low Voltage Steel Tape Armoured Cable
  • IEC Standard Low Voltage Steel Tape Armoured Cable

IEC Standard Low Voltage Steel Tape Armoured Cable

Application: Construction, Underground, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Current: DC & AC
Insulation Material: XLPE
Sheath Material: PVC
Material Shape: Round Wire
Samples:
US$ 0/Meter 1 Meter(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
armoured cable
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE, RoHS
Model
Low Voltage Cables
Brand
Luxing Cables
Normal Sectional Area
1.5-800mm2
Armoured
Steel Tape Armoured,Steel Wire Armoured
Standard
IEC, BS, VDE, GB/T
Transport Package
Wooden Drum, Steel Wooden Drum, Steel Iron Drum
Specification
0.6/1kv
Trademark
CHANG QING TENG
Origin
Dezhou, Shandong
HS Code
8544492100
Production Capacity
1000000meters/Month

Product Description

IEC standard low voltage Steel tape armoured cable

IEC Standard Low Voltage Steel Tape Armoured Cable IEC Standard Low Voltage Steel Tape Armoured Cable IEC Standard Low Voltage Steel Tape Armoured Cable


1.Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors,
in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants,
where there is no risk of mechanical damage.

2.Construction

1)Conductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, 
or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2)Insulation
XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90C continuous operation.
3)Colour Code

Colour Code (1)

1 Core Red or Black
2 Cores Red, Black
3 Cores Red, Yellow, Blue
4 Cores Red, Yellow, Blue, Black
5 Cores Red, Yellow, Blue, Black, Green
Above 5 Cores Black Cores with White numerals

Colour Code (2)

1 Core Brown or Blue
2 Cores Brown, Blue
3 Cores Brown, Black, Grey
4 Cores Blue, Brown, Black, Grey
5 Cores Green/Yellow, Blue, Brown, Black, Grey
Above 5 Cores Black Cores with White numerals
Other colours can be manufactured upon request.
4)Assembly / Inner Covering
The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores,
a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled.
A suitable binder is permitted before application of an extruded inner covering.
The material is compatible with the insulating material,
The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with
the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
5)Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1,
or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.

IEC Standard Low Voltage Steel Tape Armoured Cable
6)Outer Sheath

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7,
Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
7)Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22,
IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

3.Cable Parameters

1)Single core low voltage cables (unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
1x1.5 1.4 0.7 1.4 5.6
1x2.5 1.8 0.7 1.4 6.0
1x4 2.3 0.7 1.4 6.5
1x6 2.8 0.7 1.4 7.0
1x10 3.6 0.7 1.4 7.8
1x16 4.5 0.7 1.4 8.7
1x25 5.6 0.9 1.4 10.2
1x35 6.7 0.9 1.4 11.3
1x50 8.0 1 1.4 12.8
1x70 9.4 1.1 1.4 14.4
1x95 11.0 1.1 1.5 16.1
1x120 12.4 1.2 1.5 17.8
1x150 13.8 1.4 1.6 19.8
1x185 15.3 1.6 1.6 21.8
1x240 17.5 1.7 1.7 24.4
1x300 19.5 1.8 1.8 26.7
1x400 22.6 2 1.9 30.5
1x500 25.2 2.2 2.0 33.7
1x630 28.3 2.4 2.2 37.4
1x800 31.9 2.6 2.3 41.7
1x1000 35.7 2.8 2.4 46.2


2)Two cores low voltage cables (unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
2x1.5 1.4 0.7 1.8 9.2
2x2.5 1.8 0.7 1.8 10.0
2x4 2.3 0.7 1.8 11.0
2x6 2.8 0.7 1.8 12.0
2x10 3.6 0.7 1.8 13.6
2x16 4.5 0.7 1.8 15.4
2x25 5.6 0.9 1.8 18.4
2x35 6.7 0.9 1.8 20.6
2x50 8.0 1 1.8 23.6
2x70 9.4 1.1 1.8 26.8
2x95 11.0 1.1 1.9 30.2
2x120 12.4 1.2 2.0 33.7
2x150 13.8 1.4 2.2 37.5
2x185 15.3 1.6 2.3 41.6
2x240 17.5 1.7 2.5 46.7
2x300 19.5 1.8 2.6 51.4
2x400 22.6 2 2.9 58.9


3)Three cores low voltage cables (unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
3x1.5 1.4 0.7 1.8 9.6
3x2.5 1.8 0.7 1.8 10.5
3x4 2.3 0.7 1.8 11.6
3x6 2.8 0.7 1.8 12.6
3x10 3.6 0.7 1.8 14.4
3x16 4.5 0.7 1.8 16.3
3x25 5.6 0.9 1.8 19.5
3x35 6.7 0.9 1.8 21.9
3x50 8.0 1 1.8 25.1
3x70 9.4 1.1 1.9 28.7
3x95 11.0 1.1 2.0 32.4
3x120 12.4 1.2 2.1 36.1
3x150 13.8 1.4 2.3 40.3
3x185 15.3 1.6 2.4 44.6
3x240 17.5 1.7 2.6 50.2
3x300 19.5 1.8 2.7 55.2
3x400 22.6 2 3.0 63.3


4)Three cores+1 low voltage cables (unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 (3)mm (1)mm (3)mm (1)mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1.8 17.5
3x 25/16 5.6 4.5 0.9 0.7 1.8 21.2
3x 35/16 6.7 4.5 0.9 0.7 1.8 23.8
3x 50/25 8 5.6 1 0.9 1.8 27.5
3x 70/35 9.4 6.7 1.1 0.9 2.0 31.7
3x 95/50 11 8 1.1 1 2.1 35.8
3x120/70 12.4 9.4 1.2 1.1 2.3 39.9
3x150/70 13.8 9.4 1.4 1.1 2.4 44.6
3x185/95 15.3 11 1.6 1.1 2.6 49.5
3x240/120 17.5 12.4 1.7 1.2 2.8 55.7
3x300/150 19.5 13.8 1.8 1.4 3.0 61.4
3x400/185 22.6 15.3 2 1.6 3.2 70.4


5)Four cores low voltage cables (unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
4x1.5 1.4 0.7 1.8 10.4
4x2.5 1.8 0.7 1.8 11.3
4x4 2.3 0.7 1.8 12.5
4x6 2.8 0.7 1.8 13.7
4x10 3.6 0.7 1.8 15.7
4x16 4.5 0.7 1.8 17.8
4x25 5.6 0.9 1.8 21.5
4x35 6.7 0.9 1.8 24.1
4x50 8.0 1 1.8 27.8
4x70 9.4 1.1 2.0 32.0
4x95 11.0 1.1 2.1 36.1
4x120 12.4 1.2 2.3 40.2
4x150 13.8 1.4 2.4 44.9
4x185 15.3 1.6 2.6 49.8
4x240 17.5 1.7 2.8 56.0
4x300 19.5 1.8 3.0 61.7
4x400 22.6 2 3.2 70.7


6)Multi-cores low voltage cables(unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
5x1.5 1.4 0.7 1.8 11.2
7x1.5 1.4 0.7 1.8 12.0
10x1.5 1.4 0.7 1.8 14.8
12x1.5 1.4 0.7 1.8 15.2
14x1.5 1.4 0.7 1.8 16.0
19x1.5 1.4 0.7 1.8 17.6
21x1.5 1.4 0.7 1.8 18.4
24x1.5 1.4 0.7 1.8 20.4
30x1.5 1.4 0.7 1.8 21.6
40x1.5 1.4 0.7 1.8 26.0
48x1.5 1.4 0.7 1.8 26.4
61x1.5 1.4 0.7 1.9 29.0
5x2.5 1.8 0.7 1.8 12.2
7x2.5 1.8 0.7 1.8 13.2
10x2.5 1.8 0.7 1.8 16.4
12x2.5 1.8 0.7 1.8 16.9
14x2.5 1.8 0.7 1.8 17.7
19x2.5 1.8 0.7 1.8 19.6
21x2.5 1.8 0.7 1.8 20.6
24x2.5 1.8 0.7 1.8 22.8
30x2.5 1.8 0.7 1.8 24.1
40x2.5 1.8 0.7 1.9 29.4
48x2.5 1.8 0.7 1.9 29.9
61x2.5 1.8 0.7 2.0 32.8


7)Single core low voltage cables ( aluminum wire armoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Alum Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
1x4 2.3 0.7 1.0 0.8 1.8 10.9
1x6 2.8 0.7 1.0 0.8 1.8 11.4
1x10 3.6 0.7 1.0 0.8 1.8 12.2
1x16 4.5 0.7 1.0 0.8 1.8 13.1
1x25 5.6 0.9 1.0 0.8 1.8 14.6
1x35 6.7 0.9 1.0 1.25 1.8 16.6
1x50 8.0 1 1.0 1.25 1.8 18.1
1x70 9.4 1.1 1.0 1.25 1.8 19.7
1x95 11.0 1.1 1.0 1.6 1.8 22.0
1x120 12.4 1.2 1.0 1.6 1.8 23.6
1x150 13.8 1.4 1.0 1.6 1.8 25.4
1x185 15.3 1.6 1.0 1.6 1.8 27.4
1x240 17.5 1.7 1.0 1.6 1.9 29.9
1x300 19.5 1.8 1.0 2.0 2.0 33.1
1x400 22.6 2 1.2 2.0 2.2 37.3
1x500 25.2 2.2 1.2 2.0 2.3 40.


8)Two cores low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
2x1.5 1.4 0.7 1.0 0.8 1.8 12.8
2x2.5 1.8 0.7 1.0 0.8 1.8 13.6
2x4 2.3 0.7 1.0 0.8 1.8 14.6
2x6 2.8 0.7 1.0 1.25 1.8 16.5
2x10 3.6 0.7 1.0 1.25 1.8 18.1
2x16 4.5 0.7 1.0 1.25 1.8 19.9
2x25 5.6 0.9 1.0 1.6 1.8 23.6
2x35 6.7 0.9 1.0 1.6 1.8 25.8
2x50 8.0 1 1.0 1.6 1.9 29.0
2x70 9.4 1.1 1.0 2.0 2.0 33.2
2x95 11.0 1.1 1.2 2.0 2.1 37.1
2x120 12.4 1.2 1.2 2.0 2.3 40.5
2x150 13.8 1.4 1.2 2.5 2.4 45.4
2x185 15.3 1.6 1.4 2.5 2.6 49.9
2x240 17.5 1.7 1.4 2.5 2.7 55.1
2x300 19.5 1.8 1.6 2.5 2.9 60.2
2x400 22.6 2 1.6 2.5 3.1 67.7


9)Three cores low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
3x1.5 1.4 0.7 1.0 0.8 1.8 13.2
3x2.5 1.8 0.7 1.0 0.8 1.8 14.1
3x4 2.3 0.7 1.0 0.8 1.8 15.2
3x6 2.8 0.7 1.0 1.25 1.8 17.1
3x10 3.6 0.7 1.0 1.25 1.8 18.9
3x16 4.5 0.7 1.0 1.25 1.8 20.8
3x25 5.6 0.9 1.0 1.6 1.8 24.7
3x35 6.7 0.9 1.0 1.6 1.8 27.2
3x50 8.0 1 1.0 1.6 1.9 30.6
3x70 9.4 1.1 1.0 2.0 2.1 35.2
3x95 11.0 1.1 1.2 2.0 2.2 39.3
3x120 12.4 1.2 1.2 2.0 2.3 43.0
3x150 13.8 1.4 1.4 2.5 2.5 48.6
3x185 15.3 1.6 1.4 2.5 2.7 53.0
3x240 17.5 1.7 1.4 2.5 2.8 58.5
3x300 19.5 1.8 1.6 2.5 3.0 64.0
3x400 22.6 2 1.6 3.15 3.3 73.5


10)Three cores+1 low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 (3) mm (1) mm (3) mm (1) mm mm mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1 1.6 1.8 22.7
3x 25/16 5.6 4.5 0.9 0.7 1 1.6 1.8 26.5
3x 35/16 6.7 4.5 0.9 0.7 1 1.6 1.9 29
3x 50/25 8.0 5.6 1 0.9 1 1.6 2.1 33
3x 70/35 9.4 6.7 1.1 0.9 1.2 2 2.2 38
3x 95/50 11.0 8.0 1.1 1 1.2 2 2.3 42.4
3x120/70 12.4 9.4 1.2 1.1 1.2 2 2.5 48.0
3x150/70 13.8 9.4 1.4 1.1 1.4 2.5 2.7 52
3x185/95 15.3 11.0 1.6 1.1 1.4 2.5 2.8 57.2
3x240/120 17.5 12.4 1.7 1.2 1.6 2.5 3.1 64
3x300/150 19.5 13.8 1.8 1.4 1.6 2.5 3.2 69.8
3x400/185 22.6 15.3 2 1.6 1.6 3.15 3.6 78.6


11)Four cores low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
4x1.5 1.4 0.7 1.0 0.8 1.8 14.0
4x2.5 1.8 0.7 1.0 0.8 1.8 14.9
4x4 2.3 0.7 1.0 1.25 1.8 17.0
4x6 2.8 0.7 1.0 1.25 1.8 18.2
4x10 3.6 0.7 1.0 1.25 1.8 20.2
4x16 4.5 0.7 1.0 1.6 1.8 23.0
4x25 5.6 0.9 1.0 1.6 1.8 26.7
4x35 6.7 0.9 1.0 1.6 1.9 29.5
4x50 8.0 1 1.0 2.0 2.1 34.2
4x70 9.4 1.1 1.2 2.0 2.2 38.8
4x95 11.0 1.1 1.2 2.0 2.3 42.9
4x120 12.4 1.2 1.4 2.5 2.5 48.6
4x150 13.8 1.4 1.4 2.5 2.7 53.2
4x185 15.3 1.6 1.4 2.5 2.8 58.1
4x240 17.5 1.7 1.6 2.5 3.1 64.8
4x300 19.5 1.8 1.6 2.5 3.2 70.4
4x400 22.6 2 1.8 3.15 3.6 81.3

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Registered Capital
51.73 Million USD
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018