Customization: | Available |
---|---|
Type: | Insulated |
Conductor Type: | Stranded |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1,This cable is produced according to the standard BS6500,IEC60227:1993, VDE 0281
2,BS6360 Class 5,Solid or Stranded Bare Copper Conductor
3,BS7655 TI 1 PVC Insulation
4,PVC Sheathed, color available
Application:The cable is suitable to be fixed wiring of power device,power lighting of home electric equipment and instrument, inner wiring of electric enquipment Instrument, electron equipment, automatization device etc.
Suitable for use in conduit and for fixed, protected installation of Wiring Burglar Alarm, Public
Address Systems,Intercoms, Telephone Stations, Speakers, Instrumentation, Control and other
Low Voltage Circuits that are Power Limited and anti-interference needed
electric wire cable 35mm2 AWG cable from Yanggu factory
Type | Electric wire |
Voltage | Low voltage 450/750 V |
Insulation | PVC |
Jacket | Non-sheathed |
Core | single |
Nominal cross area | 35mm2 |
Outer diameter | 10.3mm |
Weight | 0.36kg |
Application | Housing applicance |
CCC Approval Rubber Cable
Type |
Structure |
Standard |
Rate Voltage |
Rate Temperature |
Application |
60227IEC05 (BV) |
Class 1 Copper Conductor, PVC Insulation |
GB5023 IEC60227 GB19666 |
300/500V |
70ºC |
Suitable for power installations, household appliances, instrumentation and communication devices. Usually used for indoor wiring. |
60227IEC01 (BV) |
Class 1 and Class 2 Copper Conductor, PVC Insulation |
GB5023 IEC60227 |
450/750V |
70ºC |
|
BVV |
Class 1 and Class 2 Copper Conductor, PVC Insulation, PVC Jacket |
GB5023 IEC60227 JB8734 |
450/750V |
70ºC |
Suitable for power installations, household appliances, instrumentation and communication devices. Usually used as connect line of outdoor air conditioner. |
BVR |
Copper Conductor, PVC Insulation |
JB8734 |
450/750V |
70ºC |
Used for fixed wiring in condition that needs flexibility. |
NH-BV |
Class 1 and Class 2 Copper Conductor, Mica Fireproof layer, PVC Insulation |
GB5023 GB1966 |
450/750V |
70ºC |
Used for industrial system, key plant, multiple usage warehousing, important building. When fire occur, this cable can keep the circuit normal in a certain time. |
NH-BVV |
Class 1 and Class 2 Copper Conductor, Mica Fireproof layer, PVC Insulation, PVC Jacket |
GB5023 IEC60227 GB19666 |
450/750V |
70ºC |
|
60227IEC02 (RV) |
Stranded Bare Copper Conductor, PVC Insulation |
GB5023 |
450/750V |
70ºC |
Mainly used at middle and light style moving electronics, home appliances, power tools and lighting and the places where flexible required. |
60227IEC06 (RV) |
Stranded Bare Copper Conductor, PVC Insulation |
GB5023 |
300/500V |
70ºC |
|
60227IEC52 (RVV) |
Stranded Bare Copper Conductor, PVC Insulation, PVC Jacket |
GB5023 |
300/300V |
70ºC |
|
60227IEC53 (RVV) |
Stranded Bare Copper Conductor, PVC Insulation, PVC Jacket |
GB5023 |
300/500V |
70ºC |
|
60227IEC08 (RV-90) |
Stranded Bare Copper Conductor, PVC Insulation |
GB5023 |
300/500V |
90ºC |
Used as connectors of driving, lighting, electric equipment, instrument and telecommunication equipment. Mainly used at the places where heat resistance is required. |
RVVP |
Stranded Bare Copper Conductor, PVC Insulation, PVC Jacket |
JB8734 |
300/300V |
70ºC |
Used as a connect wire for electric equipment. Also can be used as a signal control cable. Suitable for condition of mobile usage, moisture-proofing or anti-interference |
Main technical parameters:
specification | diameter of wires in stranded conductor | Insulation nominal thickness /mm | sheath nominal thickness /mm | Max. DC resistance 20ºC (Ω/km) | |
copper conductor | tinning conductor | ||||
2×0.5 | 16/0.20 | 0.6 | 0.6 | 39.0 | 40.1 |
2X0.75 | 24/0.20 | 0.8 | 0.8 | 26.0 | 26.7 |
2X1 | 32/0.20 | 0.8 | 0.8 | 19.5 | 20.0 |
2X1.5 | 30/0.25 | 0.8 | 0.8 | 13.3 | 13.7 |
2X2.5 | 49/0.25 | 1 | 1 | 7.98 | 8.21 |
3×0.5 | 16/0.20 | 0.6 | 0.6 | 39.0 | 40.1 |
3X0.75 | 24/0.20 | 0.8 | 0.8 | 26.0 | 26.7 |
3X1 | 32/0.20 | 0.8 | 0.8 | 19.5 | 20 |
3X1.5 | 30/0.25 | 0.9 | 0.9 | 13.3 | 13.7 |
3X2.5 | 49/0.25 | 1.1 | 1.1 | 7.98 | 8.21 |
4X0.75 | 24/0.20 | 0.8 | 0.8 | 26.0 | 26.7 |
4X1 | 32/0.20 | 0.9 | 0.9 | 19.5 | 20.0 |
4X1.5 | 30/0.25 | 1 | 1 | 13.3 | 13.7 |
4X2.5 | 49/0.25 | 1.1 | 1.1 | 7.98 | 8.21 |
5X0.75 | 24/0.20 | 0.9 | 0.9 | 26.0 | 26.7 |
5X1 | 32/0.20 | 0.9 | 0.9 | 19.5 | 20.0 |
5X1.5 | 30/0.25 | 1.1 | 1.1 | 13.3 | 13.7 |
5X2.5 | 49/0.25 | 1.2 | 1.2 | 7.98 | 8.21 |
Exhibition:
Certificates
Packaging & Shipping
All cable For exporting are well packed and protected by wooden drum or Wood and Steel Drum.
The packing material is depended on the weight and size of cable.
The good information, manufacture information, and the client's information is firmly printed on each size of drum.
The size of the container is chosed according to weight of total loaded goods or as per the client's requirement.