Customization: | Available |
---|---|
Application: | Construction, Underground, Industrial, Power Station |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of US$ 0/Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Cable Structure:
1. Conductor: Copper(Cu) or Aluminum
2. PVC insulation
3. Fill layer
4. Around the package tape
5. Inner Sheath
6. Steel tape armor
7. Outer Sheath
8. Mark
Product Description:
PVC insulated PVC sheathed power cable (PVC/PVC Cable)
PVC insulated steel tape armored PVC sheathed power cable (PVC/STA/PVC Cable)
PVC insulated steel wire armored PVC sheathed power cable (PVC/SWA/PVC Cable)
Flame retardant PVC insulated PVC sheathed power cable (FR/PVC/PVC Cable)
Flame retardant PVC insulated steel tape armored PVC sheathed power cable (FR/PVC/STA/PVC Cable)
Flame retardant PVC insulated steel wire armored PVC sheathed power cable (FR/PVC/SWA/PVC Cable)
Application:
1.steel-tape armored cable is to be laid underground, the cable could bear certain mechanical force.
2.Steel-wire cable is applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint.
Standard: This product adopts the standards of IEC502 & IEC332-3
Scope of application: This item is applied for the alternating current circuitry with voltage (Uo/U) 0.6/1kV for the power supply.
Working conditions:
1) This maximum working temperature of the conductor is 70°C.
2) During having a short(lasting less than 5 seconds)the maximum temperature of the cable conductor for shall not be above 160°C.
3) Environment temperature should be no lower than 0°C for laying the cable;
4) Bending radius allowance of the cable;
single core cable: no steel tape cable 20D: steel tape cable 15D.
3 core cable: no steel tape cable 15D; steel tape cable 12D.
Notes: D practical external diameter of cable
Type, Description & Application of cable
Type |
Description |
Main application |
VV VLV |
PVC insulation PVC sheath power cable |
For laying in door, inducts and kin tunnels, but unable to bear pulling force and pressure. |
VV22 VLV22 |
PVC insulated steel tape armored PVC sheathed power cable |
For laying in doors, in tunnels and direct in ground, able to bear pulling force and pressure. |
VV32 VLV32 |
PVC insulated fine steel wire armored PVC sheathed power cable |
For laying down wells and under water, able to bear certain axis pulling force. |
VV42 VLV42 |
PVC insulated steel wire armored PVC sheathed power cable |
For laying down wells and under water, able to bear certain pulling force. |
ZR-VV ZR-VLV |
PVC insulated PVC sheathed flame retardant power cable |
For laying in door, inducts and in tunnels, but unable to bear pulling force and pressure. |
ZR-VV22 ZR-VLV22 |
PVC insulated steel tape armored PVC sheathed flame retardant power cable |
For laying in doors, in tunnels and directing ground, able to bear pulling force and pressure. |
ZR-VV32 ZR-VLV32 |
PVC insulated fine steel wire armored PVC sheathed flame retardant power cable |
For laying in doors, in wells, under water, able to bear certain pulling force. |
ZR-VV42 ZR-VLV42 |
PVC insulated steel wire armored PVC sheathed flame retardant power cable |
For laying down wells and under water, able to bear certain axis pulling force. |
Core numbers & nominal cross-section area: see Table 2-2
Core No |
1 |
2 |
3 |
3+1 |
4 |
3+2 |
4+1 |
5 |
Area |
4~500 |
2.5~500 |
2.5~300 |
4~300 |
2.5~300 |
2.5~300 |
4~300 |
2.5~95 |
Main properties
No |
Test item |
Property |
|||
1 |
Construction |
Listed to the tables |
|||
2 |
Conductor resistance |
Listed to the tables |
|||
3 |
Voltage test |
A.C 3.5kV 5min |
No breaken |
||
4 |
Mechanical properties before aging |
Tensile strength |
Insulation |
Min.12.5N/mm² |
|
Sheath |
Min.12.5N/mm² |
||||
Elongation at break |
Insulation |
Min.150% |
|||
Sheath |
Min.150% |
||||
Mechanical properties after aging |
Tensile strength |
Insulation |
100°C±2°C 7days Min.±12.5N/mm² |
||
Sheath |
100°C±2°C 7days Min.±12.5N/mm² |
||||
Varying valve of tensile strength |
Insulation |
100°C±2°C 7days Min.±25% |
|||
Sheath |
100°C±2°C 7days Min.±25% |
||||
Elongation at break |
Insulation |
100°C±2°C 7days Min.±150% |
|||
Sheath |
100°C±2°C 7days Min.±150% |
||||
Varying valve of tensile strength |
Insulation |
100°C±2°C 7days Min.±25% |
|||
Sheath |
100°C±2°C 7days Min.±25% |
||||
5 |
Flame-retardant property |
Comply with GB12666.5-90(CB) and IEC332-3(CB) |
|||
6 |
Constant of insulation resistivity |
Min at 20°C |
36.7 |
||
Ki MΩ.km |
Min at 70°C |
0.037 |
0.6/1Kv PVC Insulated Steel Tape Armored PVC Sheathed Flame Retardant and Non-flame
Nom.cross sec.area of conductor |
Single quantity of Conductor |
Insu. |
Steel tape thickness |
Outer sheath thickness |
Approx. |
Cable approx. |
D.C. |
Test voltage |
||
Cu |
Al |
20°CCu |
20°CAl |
Kv/5min |
||||||
2x4 |
1 |
1.0 |
2x0.2 |
1.8 |
14.6 |
210 |
160 |
4.61 |
7.41 |
3.5 |
2x6 |
1 |
1.0 |
2x0.2 |
1.8 |
15.6 |
264 |
192 |
3.08 |
4.61 |
3.5 |
2x10 |
7 |
1.0 |
2x0.2 |
1.8 |
18.2 |
393 |
242 |
1.83 |
3.02 |
3.5 |
2x16 |
7 |
1.0 |
2x0.2 |
1.8 |
20.3 |
541 |
334 |
1.15 |
1.91 |
3.5 |
2x25 |
7 |
1.2 |
2x0.2 |
1.8 |
23.7 |
794 |
469 |
0.727 |
1.20 |
3.5 |
2x35 |
7 |
1.2 |
2x0.2 |
1.8 |
25.9 |
1037 |
585 |
0.524 |
0.868 |
3.5 |
2x50 |
19 |
1.4 |
2x0.2 |
1.8 |
22.6 |
1227 |
610 |
0.387 |
0.641 |
3.5 |
2x70 |
19 |
1.4 |
2x0.2 |
1.9 |
25.0 |
1650 |
747 |
0.268 |
0.443 |
3.5 |
2x95 |
19 |
1.6 |
2x0.5 |
2.1 |
30.2 |
2213 |
988 |
0.193 |
0.320 |
3.5 |
2x120 |
19 |
1.6 |
2x0.5 |
2.2 |
33.6 |
2733 |
1186 |
0.153 |
0.253 |
3.5 |
2x150 |
37 |
1.8 |
2x0.5 |
2.4 |
35.6 |
3396 |
1462 |
0.124 |
0.206 |
3.5 |
2x185 |
37 |
2.0 |
2x0.5 |
2.5 |
38.8 |
4112 |
1726 |
0.0991 |
0.164 |
3.5 |
300/500V 450/750V electrical wire | AAC conductor |
600/1000V PVC insulated cable | AAAC conductor |
600/1000V XLPE insulated cable | ACSR conductor |
1.8/3KV to 26/35KV power cable | OPGW |
Armored underground cable | ABC cable |
Control cable and instrumentation cables | Rubber cable |
Strict Quality Test
Packaging & Shipping
Why choose us
1.18 years manufacturing experience
2.Professional international trade team
3.Delivery on time
4.Factory low price and high quality based on advanced technology and high work efficiency