• PVC Insulation Material and PVC Jacket H05VV- F H03VV- F IEC60227 BS6004 VDE0281 GB/T5023 Standard Cable
  • PVC Insulation Material and PVC Jacket H05VV- F H03VV- F IEC60227 BS6004 VDE0281 GB/T5023 Standard Cable
  • PVC Insulation Material and PVC Jacket H05VV- F H03VV- F IEC60227 BS6004 VDE0281 GB/T5023 Standard Cable
  • PVC Insulation Material and PVC Jacket H05VV- F H03VV- F IEC60227 BS6004 VDE0281 GB/T5023 Standard Cable
  • PVC Insulation Material and PVC Jacket H05VV- F H03VV- F IEC60227 BS6004 VDE0281 GB/T5023 Standard Cable
  • PVC Insulation Material and PVC Jacket H05VV- F H03VV- F IEC60227 BS6004 VDE0281 GB/T5023 Standard Cable

PVC Insulation Material and PVC Jacket H05VV- F H03VV- F IEC60227 BS6004 VDE0281 GB/T5023 Standard Cable

Type: Insulated
Conductor Type: Solid / Stranded
Application: Fixed Wire
Conductor Material: Copper
Sheath Material: PVC
Insulation Material: PVC
Samples:
US$ 0/Meter 1 Meter(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
H05vv- F H03vv- F
Material Shape
Round Wire
Range of Application
Lsoh / Flame -Retardant
Certification
ISO9001, CE, CCC, RoHS, VDE, GB/T Standard
Brand
Chanong Qing Teng
Product Name
H05VV- F H03VV- F
Rated Voltage
300/500V 450/750V
Conductor
Copper / Aluminum
Insulation
PVC / XLPE
Certificates
ISO CCC Ce RoHS
Origine
Shandong China
Color
Red, Yellow, Blue, Green, Yellow/Green, Black etc
MOQ
100 Meter
Packaging
100 Meter Per Roll
Shipping
by Sea, by Train, by Air
Transport Package
100 Meter One Roll Then in Nylon Bags &Wooden Case
Specification
Packed in roll then in wooden case
Trademark
Luxing
Origin
Shandong China
HS Code
8544492100
Production Capacity
10000000000

Product Description

Brief Introduction 

H05VV-F flexible pvc 3 core flexible cable  --300/500V THREE CORES COPPER CONDUCTOR PVC INSULATED PVC SHEATHED Cable

H05VV-F flexible pvc 3 core flexible cable

fits for ac voltage 300/500V and below of domestic electrical appliances of smaller size motoriace tools,of instruments,of various meters and motorized lighting installations.

PVC Insulation Material and PVC Jacket H05VV- F H03VV- F IEC60227 BS6004 VDE0281 GB/T5023 Standard Cable

 

Parameter for H05VV-F flexible pvc 3 core flexible cable

Nominal Area of Conductor Maximum Conductor Resistance at 20°c Thickness of Insulation Thickness of Outer Sheath Approx. Overall Diameter Approx. Cable Weight Standard Packing Length
Sq.mm Ohm/Km mm mm mm Kg/Km Yard/Meter
0.5* 39 0.6 0.8 7.5 60 100Y
0.75 26 0.6 0.8 8 75 100Y
1 19.5 0.6 0.8 8.4 85 100Y
1.5 13.3 0.7 0.8 9.8 120 100Y
2.5 7.98 0.8 1.1 12 175 100Y
4 4.95 0.8 1.2 13 240 1000M
6* 3.3 0.8 1.4 15.5 350 1000M
10* 1.91 1 1.4 19 535 1000M
16* 1.21 1 1.4 21.5 745 1000M
 

CE power cable

H05V-R PVC insulation cable

Product structure Technical specification
Conductor: solid bare copper single strand,single core,according to DIN VDE 0281-3, HD 21.3 S3 and IEC 60227-3 rated voltage: 300/500V
test voltage: 2000V
Insulation: PVC TI3 insulationwire colour according to VDE-0293 minimum bending radius

Fixed installation:

Movable installation:

15×D(D=outer cable diameter)

 

15×D(D=outer cable diameter)

Color: color code in accordance with HD402 operating temperature

Fixed installation:

Movable installation:

-30 to +80ºC

 

-5 to +70ºC

Standards: GB5023.6-2012 / 60227 IEC 71f(TVVB) flame resistance pass GB/T18380.1-2001 test and GB5023.6-2012
insulation resistance: >20 Gohm x cm
special characteristics:    Application:

Solid core, easy skinning, cutting, convenient installation
Comply with EU coordination standards

  
used for fixed installation inside electronical equipment and lighting apparatus on the premise of protection.if in the signal and the control circuit, suitable for surface or embedded conduit installation.Conductor higgest operating temperature can up to 90ºC in the normal use,but it can not contact other product when higher than85ºC.
Part No.

 

cores Conductor

 

Insulation

 

 

Conductor Resistance
at 20ºC MAX
Ω/km  
weight
kg/km  
Number/ diameter
n/Φ
secatonal area
S

Thickness

mm

Diameter

mm

H05V-U

1 1/0.80 0.50

0.60

2.10  39.0 9.2

H05V-U

1 1/0.97 0.75

0.60

2.20  26.0 11.4

H05V-U

1 1/1.13 1.00

0.60

2.40 19.5 13.9

H05V-K

1 28/0.15 0.50

0.60

2.50 36.0 8.7

H05V-K

1 42/0.15 0.75

0.60

2.70 24.5 11.9

H05V-K

1 32/0.20 1.00

0.60

2.80 18.1 14.0

H05V-R

7 7/0.30 1.50

0.60

2.10 39.0 7

H05V-R

7 7/0.37 0.75

0.60

2.31 26.0 10

H05V-R

7 7/0.43 1.00

0.60

2.50 19.5 24

Luxing Cable Factory PVC Insulation Material and PVC Jacket H05VV- F H03VV- F IEC60227 BS6004 VDE0281 GB/T5023 Standard Cable

Luxing Cable Factory Mainly Produce 

300/500V 450/750V electrical wire  AAC conductor 
600/1000V PVC insulated cable AAAC conductor 
600/1000V XLPE insulated cable ACSR conductor 
1.8/3KV to 26/35KV power cable  OPGW 
Armored underground cable ABC cable 
Control cable and instrumentation cables  Rubber cable

PVC Insulation Material and PVC Jacket H05VV- F H03VV- F IEC60227 BS6004 VDE0281 GB/T5023 Standard Cable
Certificates
 
PVC Insulation Material and PVC Jacket H05VV- F H03VV- F IEC60227 BS6004 VDE0281 GB/T5023 Standard Cable

Type Test Report 
PVC Insulation Material and PVC Jacket H05VV- F H03VV- F IEC60227 BS6004 VDE0281 GB/T5023 Standard Cable

Packaging & Shipping 
PVC Insulation Material and PVC Jacket H05VV- F H03VV- F IEC60227 BS6004 VDE0281 GB/T5023 Standard Cable


FAQ

1.Are you a factory or a trading company?

   We are a factory.

2.Can you provide free samples?

   Yes, we can provide free samples of our products, just contact us with the details of samples needed. 

3.What's the MOQ requirements of your products?

   Our MOQ requirement depends on actual size and cable type.


 